Skip to Main Content (Press Enter)

Logo UNILINK
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture

UNI-FIND
Logo UNILINK

|

UNI-FIND

unilink.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  1. Pubblicazioni

Modeling Robotic-Assisted Mechanical Thrombectomy Procedures with the CorPath GRX Robot: The Core-Flow Study

Articolo
Data di Pubblicazione:
2024
Abstract:
Background and purpose: Endovascular robotic devices may enable experienced neurointerventionalists to remotely perform endovascular thrombectomy. This study aimed to assess the feasibility, safety, and efficacy of robot-assisted endovascular thrombectomy compared with manual procedures by operators with varying levels of experience, using a 3D printed neurovascular model. Materials and methods: M1 MCA occlusions were simulated in a 3D printed neurovascular model, linked to a CorPath GRX robot in a biplane angiography suite. Four interventionalists performed manual endovascular thrombectomy (n = 45) and robot-assisted endovascular thrombectomy (n = 37) procedures. The outcomes included first-pass recanalization (TICI 2c-3), the number and size of generated distal emboli, and procedural length. Results: A total of 82 experimental endovascular thrombectomies were conducted. A nonsignificant trend favoring the robot-assisted endovascular thrombectomy was observed in terms of final recanalization (89.2% versus manual endovascular thrombectomy, 71.1%; P = .083). There were no differences in total mean emboli count (16.54 [SD, 15.15] versus 15.16 [SD, 16.43]; P = .303). However, a higher mean count of emboli of > 1 mm was observed in the robot-assisted endovascular thrombectomy group (1.08 [SD, 1.00] versus 0.49 [SD, 0.84]; P = .001) compared with manual endovascular thrombectomy. The mean procedural length was longer in robot-assisted endovascular thrombectomy (6.43 [SD, 1.71] minutes versus 3.98 [SD, 1.84] minutes; P < .001). Among established neurointerventionalists, previous experience with robotic procedures did not influence recanalization (95.8% were considered experienced; 76.9% were considered novices; P = .225). Conclusions: In a 3D printed neurovascular model, robot-assisted endovascular thrombectomy has the potential to achieve recanalization rates comparable with those of manual endovascular thrombectomy within competitive procedural times. Optimization of the procedural setup is still required before implementation in clinical practice.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Tomasello, Alejandro; Hernández, David; Li, Jiahui; Tiberi, Riccardo; Rivera, Eila; Vargas, Joan Daniel; Losada, Cristina; Jablonska, Magda; Esteves, Marielle; Diaz, Maria Lourdes; Cendrero, Judith; Requena, Manuel; Diana, Francesco; De Dios, Marta; Singh, Trisha; Gramegna, Laura Ludovica; Ribo, Marc
Autori di Ateneo:
DIANA FRANCESCO
Link alla scheda completa:
https://iris.unilink.it/handle/20.500.14085/17201
Pubblicato in:
AJNR, AMERICAN JOURNAL OF NEURORADIOLOGY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.6.0.0