Skip to Main Content (Press Enter)

Logo UNILINK
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture

UNI-FIND
Logo UNILINK

|

UNI-FIND

unilink.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  1. Pubblicazioni

Radial Head Prosthesis with Interconnected Porosity Showing Low Bone Resorption Around the Stem

Articolo
Data di Pubblicazione:
2025
Abstract:
Background/Objectives: Radial head arthroplasty is a commonly preferred treatment for complex, unreconstructable radial head fractures. Recent studies have raised the question of whether factors such as bone resorption may be related to failure. This observational, retrospective, multicenter, spontaneous, and non-profit study aims to assess radiological outcomes, focusing on bone resorption around the stem, for radial head replacement using a modular, cementless radial head prosthesis with interconnected porosity. Methods: A series of 42 cases was available for review. Patients underwent radial head arthroplasty using a three-dimensional-printed radial head prosthesis. Patients were eligible for inclusion if they had undergone at least one follow-up between 6 and 15 months post-operatively. A scoring system to detect bone resorption was developed and administered by two independent evaluators. Results: Forty-two patients (14 males, 28 females), with an average age of 59 ± 11 years (range: 39–80 years), were analyzed with a minimum of six months’ and a maximum of 32 months’ follow-up. At follow-up, 50 radiological evaluations were collected, with 29 showing ≤3 mm and 12 showing 3–6 mm resorption around the stem. The average resorption was 3.5 mm ± 2.3. No correlation was found between the extent of resorption and the time of follow-up. The developed scoring system allowed for a high level of correlation between the evaluators’ measurements of bone resorption. Conclusions: Radial head prosthesis with interconnected porosity provided a low stem resorption rate for patients after a radial head fracture at short-to-mid-term follow-up after the definition of a reliable and easy-to-use radiological-based classification approach. (Level of Evidence: Level IV).
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
3D-printed radial head prosthesis; bone resorption; radial head replacement; radial head trauma; radiological outcomes
Elenco autori:
Vismara, V.; Guerra, E.; Accetta, R.; Cardile, C.; Boero, E.; Aliprandi, A.; Porta, M.; Zaolino, C.; Marinelli, A.; Cazzaniga, C.; Arrigoni, P.
Autori di Ateneo:
ARRIGONI PAOLO ANGELO
Link alla scheda completa:
https://iris.unilink.it/handle/20.500.14085/66744
Pubblicato in:
JOURNAL OF CLINICAL MEDICINE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.7.2.0