Skip to Main Content (Press Enter)

Logo UNILINK
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture

UNI-FIND
Logo UNILINK

|

UNI-FIND

unilink.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  1. Pubblicazioni

Increased accuracy in component positioning using an image-less robotic arm system in primary total knee arthroplasty: a retrospective study

Articolo
Data di Pubblicazione:
2024
Abstract:
Background: Robotic-assisted total knee arthroplasty (RTKA) and navigated total knee arthroplasty (NTKA) have shown improved knee alignment and reduced radiographic outliers. Recent studies have proven that conventional mechanical alignment may not be the optimal goal for every patient. The aim of this study was to compare the accuracy of the planned implant positioning of a novel image-less robotic technique with an established navigated technique (NTKA). Method: The study is a retrospective analysis of prospectively collected data that compared the implant positioning and lower-limb alignment of 86 image-less RTKA with 86 image-less NTKA. Radiographic analysis was performed to evaluate the lower-limb overall alignment, femoral and tibial components positioning in the coronal and sagittal planes. Outliers were evaluated with a cutoff of ± 3°. Results: No difference was noted between the two groups for radiographic outliers within ± 3° from neutral (p = 0.098). The mean hip–knee–ankle angle deviation from target was 1.3° in the RTKA group compared to 1.9° in the NTKA (p < 0.001). Femoral sagittal deviation (femoral component flexion) was smaller in the RTKA group (0.9° vs 1.9°; p < 0.001). Similarly, tibial coronal deviation (0.8° vs 1.5°; p < 0.001) and tibial sagittal deviation (tibial slope) were smaller in the RTKA group compared to the NTKA group (0.9° vs 1.7°; p < 0.001). Conclusions: The RTKA group reported a substantial and significant reduced error from the planned target angles for both tibial and femoral components. No difference in terms of radiographic outliers was noted between navigation and robotic assistance.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Knee alignment; Knee flexion; Robotic surgery; Robotic-assisted total knee arthroplasty; ROSA; Total knee arthroplasty
Elenco autori:
Mancino, F.; Rossi, S. M. P.; Sangaletti, R.; Caredda, M.; Terragnoli, F.; Benazzo, F.
Autori di Ateneo:
ROSSI STEFANO MARCO PAOLO
Link alla scheda completa:
https://iris.unilink.it/handle/20.500.14085/25723
Pubblicato in:
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.6.0.0