A retrospective study on insertion torque and implant stability quotient (ISQ) as stability parameters for immediate loading of implants in fresh extraction sockets

Articolo
Data di Pubblicazione:
2019
Abstract:
To date, insertion torque value (ITV) and implant stability quotient (ISQ) obtained by the Osstell instrument are common clinical methods to assess the initial stability of an implant for a predictable loading procedure. The aim of this current study is to evaluate the ITV and ISQ as stability parameters as part of the decision-making protocol in the adoption of immediate loading in fresh extraction sockets. Materials and Methods. A total of 41 tapered implants were allocated into two groups: the test group (n = 11; 3 males and 8 females; mean age: 62.8 ± 10.7) which received 18 implants as type 1 fresh extraction sockets after teeth removal and the control group (n = 7; 4 males and 3 females; mean age: 65.4 ± 9.7) which received 23 implants placed in healed sockets for a period of at least 3 months. Both the ITV and ISQ data were recorded at the time of insertion (t0). Since ITV (test group) and ITV/ISQ (control group) values were useful for the immediate loading protocol, a screw-retained temporary crown was immediately loaded. ISQ values were recorded after a healing period of 4 months (t1). Results. ITV mean values at t0 in test and control groups were, respectively, 48.61 ± 15.39 and 70.47 ± 14.71, whereas ISQ mean values were 57.55 ± 1.93 and 72.86 ± 5.25, respectively, showing a statistically significant difference ( value < 0.001). ISQ mean values at t1 in either the test or the control group were 68.68 ± 4.20 and 74.54 ± 4.17, not showing a statistical difference. The implant survival rate was 100% in both groups, and no surgical and prosthetic complications were reported during the study. Conclusion. In conclusion, this study remarked the presence of a residual gap that influenced the ISQ during implant insertion in fresh extraction sockets making this parameter not sufficient for a conclusive decision in the immediate loading, whereas the ITV alone showed to be the best parameter for a final substantial decision.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
implant stability quotient (ISQ)
Elenco autori:
Bavetta, G.; Bavetta, G.; Randazzo, V.; Cavataio, A.; Paderni, C.; Grassia, V.; Dipalma, G.; Gargiulo Isacco, C.; Scarano, A.; De Vito, D; Cantore, S.; Ballini, A.; Inchingolo, F.
Autori di Ateneo:
BALLINI ANDREA
DIPALMA GIANNA
Link alla scheda completa:
https://iris.unilink.it/handle/20.500.14085/41277
Pubblicato in:
BIOMED RESEARCH INTERNATIONAL