Skip to Main Content (Press Enter)

Logo UNILINK
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture

UNI-FIND
Logo UNILINK

|

UNI-FIND

unilink.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  1. Pubblicazioni

Regarding Bioanalysis Lasting a Few Minutes: Automated Cooling-SPME and Fast-GC for Urinary 2-Phenyl-2-Propanol Monitoring

Articolo
Data di Pubblicazione:
2024
Abstract:
An innovative SPME head space GC–MS method, in cooling mode, using a fully automated routine, was developed to detect 2-phenyl-2-propanol, a representative urinary metabolite of cumene. Following an acid hydrolysis and derivatization step with lowered quantities of reagents, acetic anhydride and pyridine, a 30 μm polydimethylsiloxane SPME fiber was used to sample derivatized 2-phenyl-2-propanol, such as benzenemethanol,α,α-dimethyl-acetate, from the headspace. Performances of the method, optimized through experimental design, provide an LOD of 0.034 mg/L and an LOQ 0.10 mg/L, with a short sampling time necessary per sample. The method, developed on standard solutions, will be applied to both occupationally exposed and non-exposed populations.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
2-phenyl-2-propanol; GC–MS; SPME; cooling SPME; cumene; derivatization; full automation
Elenco autori:
Dugheri, Stefano; Fanfani, Niccolò; Cappelli, Giovanni; Marigliano, Antonio; Bucaletti, Elisabetta; Squillaci, Donato; Rapi, Ilaria; Venturini, Lorenzo; Pizzella, Giulia; Manetta, Sara; Pavone, Alfonso; Secchi, Michele; Rainaldi, Iacopo; Mucci, Nicola
Autori di Ateneo:
DUGHERI STEFANO
Link alla scheda completa:
https://iris.unilink.it/handle/20.500.14085/41127
Pubblicato in:
TOXICS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.6.1.0